To speak directly to our technical department please ring 09 527 1829 or e-mail info@newtonsystems.co.nz
-
-
CDM-D01
Newton System 500, Newton System 300 – Floordrain channel above a construction joint
-
CDM-D02
Newton System 500, Newton System 300 – Floordrain channel within construction joint
-
CDM-D03
Newton System 500 – Internal load bearing wall with above slab Basedrain channel
-
CDM-D04
Newton System 500 – Internal load bearing wall with Basedrain channel within slab recess
-
-
-
CDM-D05
Drainage membrane Protection of primary waterproofing -RC Wall – External – 410 GeoDrain
-
CDM-D06
Newton System 500 – Internal load bearing wall with recessed Floordrain channel offset in front of the cavity wall
-
CDM-D07
Newton System 500, Newton System 100 – Detail in plan showing internal wall isolated from retained wall with DPM so as to provide a fire check
-
CDM-D08
Newton System 500 – Termination of waterproofing membrane to treat floor joist
-
-
-
CDM-D09
Newton System 500 – Detail showing an internal wall constructed off Newton System 500 floor membrane where the perimeter Basedrain is sat within a recess to the slab/raft
-
CDM-D10A
Newton System 500, Newton System 100 – Internal Wall/Soffit junction of an earth retaining structure – Newton System 500 to walls and Newton 101F tanking membrane to soffit
-
CDM-D10B
Newton System 500, Newton System 100 – Internal Wall/Soffit junction of an earth retaining structure – Newton System 500 to walls and Newton 106 FlexProof membrane to soffit
-
CDM-D11A
Newton System 500 – Detail showing bolted items through a Newton wall membrane
-
-
-
CDM-D11B
Newton System 500 – Detail showing poured in-situ concrete element against a Newton wall membrane
-
CDM-D12A
Newton System 500, Newton System 100 – Detail showing structural steel column waterproofing variations
-
CDM-D12B
Newton System 500, Newton System 100 – Detail showing structural steel column waterproofing variations
-
CDM-D12C
Newton System 500, Detail showing structural steel column waterproofing variations
-
-
-
CDM-D13
Newton System 500 – Detail showing electrical socket fixing methods to Newton System 500 wall membrane
-
CDM-D14A
Newton System 500 – Termination of wall membrane to DPC
-
CDM-D14B
Newton System 500 – Sealing of wall membrane to physical DPC at top of retaining wall
-
CDM-D15
Typical garage specification External waterproofing of blockwork – RC Raft – Type A – 112 Aquabit – System 300 Waterbar
-
-
-
CDM-D16A
Newton System 500 – Detail showing protrusion through Newton System 500 floor membrane
-
CDM-D16B
Newton System 500 – Detail showing protrusion through Newton System 500 wall membrane
-
CDM-D17
Newton System 500 – Termination of waterproofing membrane to floor joist within protected socket
-
CDM-D18A
Typical garage specification External waterproofing of blockwork – RC Raft – Type A – 112 Aquabit – System 300 Waterbar
-
-
-
CDM-D19A
Newton System 500, Newton System 100 – Pipe through intermediate slab to allow draining of System 500 to lower level
-
CDM-D19B
Newton System 500, Newton System 100 – Pipe through intermediate slab to allow draining of System 500 to lower level
-
CDM-D19C
Newton System 500, Newton System 100 – Pipe through intermediate slab to allow draining of System 500 to lower level
-
CDM-D19D
Newton System 500, Newton System 100 – Pipe through intermediate slab to allow draining of System 500 to lower level
-
-
-
CDM-D20-3D
Newton System 500, Newton System 100 – Termination of wall membrane to light well
-
CDM-D20A
Newton System 500, Newton System 100 – Termination of wall membrane to lightwell
-
CDM-D20B
Newton System 500, Newton System 100 – Termination of wall membrane to lightwell
-
CDM-D20C
Newton System 500 – Termination of wall membrane to lightwell
-
-
-
CDM-D21A
Newton System 500 – Basedrain above slab/raft change in level
-
CDM-D21B
Newton System 500 – Basedrain within slab/raft change in level
-
CDM-D22
Newton System 500 – Termination of floor membrane to pre-formed manhole and surface gully
-
CDM-D23A
Newton Systems 500, 100 and 700 – Termination of Newton 500 to solid steps
-
-
-
CDM-D23B
Newton System 500, Newton System 200 – Termination of Newton 500 to solid steps
-
CDM-D24
Newton System 500 – Detail in plan showing fire check internal partition with Newton 508 to the wall
-
CDM-D25
Newton System 500 – Newton 508 membrane flat or negative fall soffit
-
CDM-D26
Newton System 500 – Fixing to the wall membrane of Newton System 500 showing option using MultiPlug or a stronger resin anchor fixing through the membrane
-
-
-
CDM-D27
Newton System 500 – Detail in section showing continuation of system where existing item is too close to the wall for Newton 508 installation
-
CDM-D28
Newton System 500 – Newton 508 fixed with MultiPlugs to rendered fall to flat soffit
-
CDM-D29
Newton System 500 – Newton System 500 terminating to intermediate slabs to earth retaining basement wall using recess and drainage pipe to drain through slab
-
CDM-D30
Newton System 500 – Newton Trojan Sump System as lift pit sump
-
-
-
CDM-D33
Newton System 500 – Damp and vapour control to underside of retained flat soffit
-
CDM-D34
Newton System 500 – Newton MultiPlug Halifax Wall Tie used as means of fixing and spacing wall insulation
-
CDM-D35
Newton System 500 – Stepped Floor > Detail showing method of draining where there is a change of level
-
CDM-D37A
Newton System 500 – Window reveal detail, mesh membrane
-
-
-
CDM-D37B
Newton System 500 – Window reveal detail
-
CDM-D37C
Newton System 500 – Window reveal batten and plasterboard finish
-
CDM-D37D
Newton System 500 – Window reveal meshed membrane
-
CDM-D39
Newton System 500, Newton System 100 – Detailing to kicker to internal timber frame
-
-
-
CDM-D40
Newton System 500 – Inspection port detail
-
CDM-D41
Newton System 500, Newton System 100 – Lift pit waterproofing, showing bund as barrier to water below System 500 membrane
-
CDM-D42
Newton System 500 – Connection of Basedrain to externally sited Titan-Pro sump (not shown) with 63mm O/D pipe
-
CDM-D43A
Newton System 500 – Basedrain T-Piece through cavity wall
-
-
-
CDM-D43B
Newton System 500 – Basedran T-Piece through cavity wall (See drawing CDM-RA-03)
-
CDM-D44
Newton System 500, Newton System 100 – Swimming pool waterproofing, showing bund as barrier to water below System 500
-
CDM-D45
Newton System 500 – Natural drainage
-
CDM-D46
Newton System 500 – Natural drainage detail
-
-
-
CDM-D47A
Newton System 500 – Sheet Pile
-
CDM-D47B
Newton System 500 – Secant pile
-
CDM-D47C
Newton System 500 – Contiguous Pile
-
CDM-D48A
Typical garage specification External waterproofing of blockwork – RC Raft – Type A – 112 Aquabit – System 300 Waterbar
-
-
-
CDM-D48B
Newton System 500 – Threshold detail
-
CDM-D49A
Newton System 500 – Termination at pile cap of sheet pile
-
CDM-D49B
Newton System 500 – Termination at pile cap of secant pile
-
CDM-D49C
Newton System 500 – Termination at pile cap of contiguous pile
-
-
-
CDM-D50
Newton System 500 – Newton wall membrane to a retained garden wall
-
CDM-D51
Newton System 500 – Newton wall membrane to door threshold and reveal in a vault
-
CDM-D52
Newton System 500 – Cavity drain membrane bund
-
CDM-D70A
Newton System 500, Newton System 100 – Detailing to cast in-situ concrete steps
-
-
-
CDM-D70B
Newton System 500, Newton System 100 – Detailing to cast in-situ concrete steps
-
CDM-D72A
Newton System 500, Newton System 100 – Detailing to kicker to internal RC wall
-
CDM-D72B
Newton System 500, Newton System 100 – Detailing to kicker to internal RC wall
-
A-04
Typical garage specification External waterproofing of blockwork – RC Raft – Type A – 112 Aquabit – System 300 Waterbar
-
-
-
CDM-D72C
Newton System 500, Newton System 100 – Internal RC wall abutting external retaining wall
-
CDM-D73A
Newton System 500, Detailing to concrete/insulation plinth
-
CDM-D73B
Newton System 500, Detailing to concrete/insulation plinth
-